|
For best results: this site requires that cookies be enabled for proper operation - see Legal Page for more info
|
|
Select Any of These |
Extra Modem Settings D-H for Connecting to ISP SUMMARY ======= You may be unable to connect, or have difficulty remaining connected to ISP. Some modems may require extra settings or specific configurations to connect to ISP. The following table lists extra modem settings and configurations that may help specific modems connect or maintain a connection to ISP. NOTE: Rockwell settings may work for any modem that uses the Rockwell chipset, including Boca, Zoltrix, and Zoom 14.4 modems. MORE INFORMATION ================ Manufacturer/Model Extra Settings Status Configuration -------------------------------------------------------------------------- Delrina 14.4 PCMCIA &Q6&K3 CONFIRMED None. Diamond Multimedia AT&F UNCONFIRMED Error Control
Telecommander 3500 on. Compress
Data off.
Maximum speed
setting 38400.
Diamond Multimedia AT&F CONFIRMED Error Control TeleCommander 2500 on. Compress 14.4 data/fax Data off. Diamond Multimedia \N3%C0 UNCONFIRMED Error Control TeleCommander 2500 off. 14.4 data/fax Diamond Multimedia AT&F CONFIRMED Error Control
TeleCommander 3500 on. Compress
28.8 data/fax Data off.
Maximum speed
setting 38400.
Digicom 14.4 SoftModem \N0&K4 CONFIRMED None. Digicom 14.4 &Q6&K3 CONFIRMED None. Digicom Connection 14.4+ &K3%C0 CONFIRMED Error control
off. (This is
with the
Digicom
SoftModem
drivers
installed.)
DigiCom 14.4 SoftModem TEST \N0&K4 UNCONFIRMED None. DigiCom Scout 28.8 TEST AT&F1 UNCONFIRMED None. DigiCom Connection 144+ &K3%C0 UNCONFIRMED Error Control (with SoftModem drivers off. installed) Digital DS144F Internal AT&FW2&C1&D2&K3& UNCONFIRMED Complete
Systems Modem Q5S7=60S36=7S46= initialization
138S48=7S95=47 strings do not
always work.
Contact the
manufacturer.
Digitan Digital 14.4 AT&F UNCONFIRMED Let Windows
Data/Fax detect modem as
a 14.4
Data/Fax.
(ATI4 or
ATI6=RCV144DPI)
Digitan 28.8 V.34 AT&F1 UNCONFIRMED Error Control (in HP Pavilion) off. GateWay Telepath 14.4 s11+50 CONFIRMED Install as
Telepath 14.4
or if drivers
unavailable,
install as a
Standard 14.4.
GateWay Telepath 28.8 AT&F1&K3 CONFIRMED Error Control
off.
GateWay Telepath 28.8 V6.0 AT&F1&K3 CONFIRMED Error Control
off.
GateWay Telepath 33.6 S32=16 CONFIRMED Error Control
off.
GateWay Telepath II 28.8 Unknown UNCONFIRMED Error Control PCMCIA off. GateWay Telepath II 33.6 AT&H1&K0&R2 UNCONFIRMED (ATI4= Gateway
S72=90 S9=2 Telepath II
S10=100 33.6 voice/data)
Works with USR
Sportster 28.8
driver.
GateWay Telepath II 33.6 S32=16 UNCONFIRMED Works with USR
Sportster
33.6Vi driver.
GVC F1114 VR6 Unknown UNCONFIRMED Install as a
Standard 14.4.
Hewlett-Packard Pavilion AT&F UNCONFIRMED Error Control
5030/Prometheus 14.4 off. Set Flow
Control to
Hardware.
Hewlett-Packard Pavilion S7=90S10=80 UNCONFIRMED This is used
7130 28.8 PnP for dropped
connection
issues.
To add an extra setting or to change the Use Error Control or Compress Data options, use the following steps: 1. Click Start, point to Settings, and then click Control Panel. 2. Double-click Modems. 3. Click the modem you are using, and then click Properties. 4. On the Connection tab, click Advanced. 5. In the Extra Settings box, type the appropriate extra settings. 6. Enable or disable the Use Error Control and Compress Data options as appropriate. 7. Click OK or Close until you return to Control Panel.
LAST UPDATED Thursday, 08 November 2007 18:27:01 -0600 |
Just Check out some of our sponsors |
|
COPYRIGHT 1998 - 2008 All names used are Trademarks of the respective companies Send mail to
CompanyWebmaster with
questions or comments about this web site.
|